Notes on the setting items
BAUD RATE  | 1200, 2400, 4800, 9600, 19200, 38400 (bps)  | |
Data bits  | 7, 8 (bit)  | |
Parity  | NON, EVEN, ODD  | |
Stop bits  | 1, 2 (bit)  | |
Handshake 
  | AUTO (MGL-IIc)  | HARD, ENQACK, X-PRM, SOFT  | 
MGL-IIc  | HARD, ENQACK, X-PRM, SOFT  | |
MGL-Ic1  | HARD, XONOFF  | |
Step size 
 
 
  | AUTO (MGL-IIc)  | 0.025 (mm)  | 
AUTO (MGL-Ic1)  | 0.05 (mm)  | |
MGL-IIc  | 0.025, 0.01 (mm)  | |
MGL-Ic1  | 0.05, 0.025, 0.1 (mm)  | |
Close time*1  | 3 to 60 (Seconds)  | |
- Sets the data interval for multiple sheet cutting, and the waiting time before start of dividing cutting or sorted output. The value can be set from 3 to 60 seconds. If no data is received within the time set after cutting has ended, it is determined that one set of data has ended, allowing separation from the next set of data.