"WATER TANK ROUTE" is displayed.

  • The hot water pump may be malfunctioning, or there could be a hot water leak.

Please check step by step from Procedure 1.

1. Start by turning off the remote switch, followed by turning off the main power.  Wait for a while,
  and then turn on the power in the reverse order.

2. Check if the tube at the hot water inlet is twisted or not.
* When connecting the tubes, pre-twist them to the left for easier attachment.

3. In case of possible hot water shortage, while keeping the power on, access the
 [Maintenance]> [Water FillUp] menu and follow the operation panel's instructions to refill purified water.
  Make sure to use only purified water (industrial-grade purified water is acceptable).
  If obtaining purified water is difficult, please consider purchasing
 "SPC-0783 ANTIFREEZE MIXED WATER 35WT%1L".

4. If adding purified water in step 3 does not resolve the error, drain all the hot water once and try
  preparing a new antifreeze solution for reinjection.
  Please refer to "Fill up the antifreeze water" for the procedures.


If the error is still displayed, please contact our technician or call center for assistance.