- If the vacuum unit is the original unit from MIMAKI and it is not a 3rd party vacuum unit, the vacuum and blower power is adjustable in 10 steps.
[Details]:
If the Vacuum unit is a 3rd party vacuum, you can not control the vacuum power level from JFX control panel. Even if it has inverter to control the power, you have to control it directly on the unit manually.
[Original Vacuum unit from MIMAKI]:
We have three kinds of Vacuum units, and you can choose one from the three.
It depends on the power type to choose, like what kind of power your building has.
・ P/N: OPT-J0216 (Three-phase, 200-240V, 50/60Hz, 30A or less, 3.4kW)
・ P/N: OPT-J0217 (Single-phase, 200-240V, 50/60Hz, 30A or less, 1.9kW)
・ P/N: OPT-J0232 (Three-phase, 380-480V, 50/60Hz, 20A or less, 3.4kW)
[Vacuum/Blower power change procedure]
Please refer to the following document.
『Operation manual 』-[Chapter4]-[Setting vacuuming/blowing level of the vacuum unit]